Next: Summary
Up: The ETSI Synchronisation Clock
Previous: A Contradiction: Setting the
The standards [3],[4] also specify the use of an anti-aliasing filter. A suggested filter that meets the required specifications is a first order 10Hz low pass filter with 0.2dB attenuation at the passband edge and it is this that has been used. It is also required that for observation intervals,
such that
, as were simulated, the sampling time be no greater than
and that the minimum measurement period (the minimum total simulation time) for TDEV be at least
. These result in certain simulation difficulties which are discussed in sections 7.1.2 and 7.2.
Mark J Ivens